Network Throughput and Performance Guide
Introduction
Setting up an efficient network in the world of virtual machines can be a daunting task. Hopefully, this guide will be of some help, and allow you to make good use of your network resources.
The guide applies to XCP 1.0 and later, and to XenServer 5.6 FP1 and later. Much of it is applicable to earlier versions, too.
For a general guide on XenServer network configurations, see Designing XenServer Network Configurations.
Contributing
If you would like to contribute to this guide, please submit your feedback to [rok.strnisa@citrix.com], or get an account and edit the page yourself.
If you would like to be notified about updates to this guide, please create an account and "Subscribe" to this page.
Scenarios
There are many possible scenarios where network throughput can be relevant. The major ones that we have identified are:
- dom0 throughput The traffic is sent/received directly by `dom0`.
- single-VM throughput The traffic is sent/received by a single VM.
- multi-VM throughput The traffic is sent/received by multiple VMs, concurrently. Here, we are interested in aggregate network throughput.
- single-VCPU VM throughput The traffic is sent/received by a single-VCPU VMs.
- single-VCPU single-TCP-thread VM throughput The traffic is sent/received by a single TCP thread in single-VCPU VMs.
- multi-VCPU VM throughput The traffic is sent/received by a multi-VCPU VMs.
- network throughput for storage The traffic sent/received originates from/is stored on a storage device.
Technical Overview
Sending network traffic to and from a VM is a fairly complex process. The figure applies to PV guests, and to HVM guests with PV drivers.
Therefore, when a process in a VM, e.g. a VM with domID equal to X, wants to send a network packet, the following occurs:
- A process in the VM generates a network packet P, and sends it to a VM's virtual network interface (VIF), e.g. ethY_n for some network Y and some connection n.
- The driver for that VIF, netfront driver, then shares the memory page (which contains the packet P) with the backend domain by establishing a new grant entry. A grant reference is part of the request pushed onto the transmit shared ring (Tx Ring).
- netfront then notifies, via an event channel (not on the diagram), one of netback threads in dom0 (the one responsible for ethY_n) where in the shared pages the packet P is stored. (XenStore is used to setup the initial connection between the front-end and the back-end, deciding on what event channel to use, and where the shared rings are.)
- netback (in dom0) fetches P, processes it, and forwards it to vifX.Y_n;
- The packet is then handed to the back-end network stack, where it is treated according to its configuration just like any other packet arriving on a network device.
When a VM is to receive a packet, the process is almost the reverse of the above. The key difference is that on receive there is a copy being made: it happens in dom0, and is a copy from back-end owned memory into a Tx Buf, which the guest has granted to the back-end domain. The grant references to these buffers are in the request on the Rx Ring (not Tx Ring).
Symptoms, probable causes, and advice
There are many potential bottlenecks. Here is a list of symptoms (and associated probable causes and advice):
- I/O is extremely slow on my Hardware Virtualised Machine (HVM), e.g. a Windows VM.
- Verifying the symptom: Compare the results of an I/O speed test on the problem VM and a healthy VM; they should be at least an order of magnitude different.
- Probable cause: The HVM does not have PV drivers installed.
- Background: With PV drivers, an HVM can make direct use of some of the underlying hardware, leading to better performance.
- Recommendation: Install PV drivers.
- VM's VCPU is fully utilised.
- Verifying the symptom: Run xentop in dom0 --- this should give a fairly good estimate of aggregate usage for all VCPUs of a VM; pressing V reveals how many seconds were spent in which VM's VCPU. Running VCPU measurement tools inside the VM does not give reliable results; they can only be used to find rough relative usage between applications in a VM.
- Background: When a VM sends or receives network traffic, it needs to do some basic packet processing.
- Probable cause: There is too much traffic for that VCPU to handle.
- Recommendation 1: Try enabling NIC offloading --- see Tweaks (below) on how to do this.
- Recommendation 2: Try running the application that does the sending/receiving of network traffic with multiple threads. This will give the OS a chance to distribute the workload over all available VCPUs.
- HVM VM's first (and possibly only) VCPU is fully utilised.
- Verifying the symptom: Same as above.
- Background: Currently, only VM's first VCPU can process the handling of interrupt requests.
- Probable cause: The VM is receiving too many packets for its current setup.
- Recommendation 1: If the VM has multiple VCPUs, try to associate application processing with non-first VCPUs.
- Recommendation 2: Use more (1 VCPU) VMs to handle receive traffic, and a workload balancer in front of them.
- Recommendation 3: If the VM has multiple VCPUs and there's no definite need for it to have multiple VCPUs, create multiple 1-VCPU VMs instead (see Recommendation 2).
- Plans for improvement: Underlying architecture needs to be improved so that VM's non-first VCPUs can process interrupt requests.
- In dom0, a high percentage of a single VCPU is spent processing system interrupts.
- Verifying the symptom: Run top in dom0, then press z (for colours) and 1 (to show VCPU breakdown). Check if there is a high value for si for a single VCPU.
- Background: When packets are sent to a VM on a host, its dom0 needs to process interrupt requests associated with the interrupt queues that correspond to the device the packets arrived on.
- Probable cause: dom0 is set up to process all interrupt requests for a specific device on a specific dom0 VCPU.
- Recommendation 1: Check in /proc/interrupts whether your device exposes multiple interrupt queues. If the device supports this feature, make sure that it is enabled.
- Recommendation 2: If the device supports multiple interrupt queues, distribute the processing of them either automatically (by using irqbalance daemon), or manually (by setting /proc/irq/<irq-no>/smp_affinity) to all (or a subset of) dom0 VCPUs.
- Recommendation 3: Otherwise, make sure that an otherwise relatively-idle dom0 VCPU is set to process the interrupt queue (by manually setting the appropriate /proc/irq/<irq-no>/smp_affinity).
- In dom0, a VCPU is fully occupied with a netback process.
- Verifying the symptom: Run top in dom0. Check if there is a netback process, which appears to be taking almost 100%. Then, run xentop in dom0, and check VCPU usage for dom0: if it reads about 120% +/- 20% when there is no other significant process in dom0, then there's a high chance that you have confirmed the symptom.
- Background: When packets are sent from or to a VM on a host, the packets are processed by a netback process, which is dom0's side of VM network driver (VM's side is called netfront).
- General Recommendation: Try enabling NIC offloading --- see Tweaks (below) on how to do this.
- Possible cause 1: VMs' VIFs are not correctly distributed over the available netback threads.
- Recommendation: Read the related KB article.
- Possible cause 2: Too much traffic is being sent of a single VIF.
- Recommendation: Create another VIF for the corresponding VM, and setup the application(s) within the VM to send/receive traffic over both VIFs. Since each VIF should be associated with a different netback process (each of which is linked to a different dom0 VCPU), this should remove the associated dom0 bottleneck. If every dom0 netback thread is taking 100% of a dom0 VCPU, increase the number of dom0 VCPUs and netback threads first --- see Tweaks (below) on how to do this.
- There is a VCPU bottleneck either in a dom0 or in a VM, and I have control over both the sending and the receiving side of the network connection.
- Verifying the symptom: (See notes about xentop and top above.)
- Background: (Roughly) Each packet generates an interrupt request, and each interrupt request requires some VCPU capacity.
- Recommendation: Enable Jumbo Frames (see Tweaks (below) for more information) for the whole connection. This should decrease the number of interrupts, and therefore decrease the load on the associated VCPUs (for a specific amount of network traffic).
- There is obviously no VCPU bottleneck either in a dom0 or in a VM --- why is the framework not making use of the spare capacity?
- Verifying the symptom: (See notes about xentop and top above.)
- Background: There are many factors involved when doing network performance, and many more when using virtual machines.
- Possible cause 1: Part of the connection has reached its physical throughput limit.
- Recommendation 1: Verify that all network components in the connection path physically support the desired network throughput.
- Recommendation 2: If a physical limit has been reached for the connection, add another network path, setup appropriate PIFs and VIFs, and configure the application(s) to use both/all paths.
- Possible cause 2: Some parts of the software associated with network processing might not be completely parallelisable, or the hardware cannot make use of its parallelisation capabilities if the software doesn't follow certain patterns of behaviour.
- Recommendation 1: Setup the application used for sending or receiving network traffic to use multiple threads. Experiment with the number of threads.
- Recommendation 2: Experiment with the TCP parameters, e.g. window size and message size --- see Tweaks (below) for recommended values.
- Recommendation 3: If IOMMU is enabled on your system, try disabling it. See Tweaks for a section on how to disable IOMMU.
- Recommendation 4: Try switching the network backend. See the Tweaks section on how do that.
Making throughput measurements
When making throughput measurements, it is a good idea to start with a simple environment. For example, if testing VM-level receive throughput, try sending traffic from a bare-metal (Linux) host to VM(s) on another (XCP/XenServer) host, and vice-versa when testing VM-level transmit throughput. Transmitting traffic is less demanding on the resources, and is therefore expected to produce substantially better results.
The following sub-sections provide more information about how to use some of the more common network performance tools.
Iperf 2.0.5
Installation
Linux
Make sure the following packages are installed on your system: `gcc`, `g++`, `make`, and `subversion`.
Iperf can be installed from Iperf's SVN repository:
svn co https://iperf.svn.sourceforge.net/svnroot/iperf iperf cd iperf/trunk ./configure make make install cd iperf --version # should mentioned pthreads
Windows
You can use the following executable: iperf.exe
Note that we are not the authors of the above executable. Please use your anti-virus software to scan the file before using it.
Usage
We recommend the following usage of `iperf`:
- make sure that firewall is disabled/allows `iperf` traffic;
- set `iperf` what units to report the results in, e.g. by using `-f m` --- if
not set explicitly, `iperf` will change units based on the result;
- an `iperf` test should last at least 20 seconds, e.g. `-t 20`;
- experiment with multiple communication threads, e.g. `-P 4`;
- repeat a test in a specific context at least 5 times, calculating an average,
and making notes of any anomalies;
- experiment with TCP window size and buffer size settings --- using `-w 256K
-l 256K` for both the receiver and the sender worked well for us;
- use a shell/batch script to start multiple `iperf` processes simultaneously
(if required), and possibly to automate the whole testing process.
- when running `iperf` on a Windows VM:
- run it in non-daemon mode on the receiver, since daemon mode tends to (it's
still unclear as to when exactly) create a service. Having an `iperf` service is undesirable, since one cannot as easily control which VCPU it executes on, and with what priority. Also, you cannot have multiple receivers with a service running (in case you wanted to experiment with them);
- run `iperf` with "realtime" priority, and on a non-first VCPU (if you are
executing on a multi-VCPU VM) for reasons explained in the section above.
Here are the simplest commands to execute on the receiver, and then the sender:
# on receiver iperf -s -f m -w 256K -l 256K # on sender iperf -c <receiver-IP> -f m -w 256K -l 256K -t 20
To measure aggregate receive throughput of multiple VMs where the data is sent
from a single source (e.g., a different physical machine), use:
#!/bin/bash VMS=$1 THREADS=$2 TIME=$3 TMP=`mktemp` for i in `seq $VMS`; do VM_IP="192.168.1.$i" # use your IP scheme here echo "Starting iperf for $VM_IP ..." iperf -c $VM_IP -w 256K -l 256K -t $TIME -f m -P $THREADS | grep -o "[0-9]\+ Mbits/sec" | awk -vn=$i '{print n, $1}' >> $TMP & done sleep $((TIME + 3)) cat $TMP | sort cat $TMP | awk '{sum+=$2}END{print "Average: ", sum}' rm -rf $TMP
Netperf 2.5.0
`netperf`'s `TCP_STREAM` test also tends to give reliable results. However, since this version (the only version we recommend using) does not automatically parallelise over the available VCPUs, such parallelisation needs to be done manually in order to make better use of the available VCPU capacity.
Installation
Linux
Make sure the following packages are installed on your system: `gcc`, `g++`, `make`, and `wget`.
Then run the following commands:
wget ftp://ftp.netperf.org/netperf/netperf-2.5.0.tar.gz tar xzf netperf-2.5.0.tar.gz cd netperf-2.5.0 ./configure make make check make install
The receiver side can then be stated manually with `netserver`, or you can
configure it as a service:
# these commands may differ depending on your OS echo "netperf 12865/tcp" >> /etc/services echo "netperf stream tcp nowait root /usr/local/bin/netserver netserver" >> /etc/inetd.conf /etc/init.d/openbsd-inetd restart
Windows
You can use the following executables:
Note that we are not the authors of the above executables. Please use your anti-virus software to scan the files before using them.
Usage
Here, we describe the usage of the Linux version of Netperf. The syntax for the Windows version is sometimes different; please see `netclient.exe -h` for more information.
With `netperf` installed on both sides, the following script can be used on either side to determine network throughput for transmitting traffic:
#!/bin/bash THREADS=$1 TIME=$2 DST=$3 TMP=`mktemp` for i in `seq $THREADS`; do netperf -H $DST -t TCP_STREAM -P 0 -c -l $TIME >> $TMP & done sleep $((TIME + 3)) cat $TMP | awk '{sum+=$5}END{print sum}' rm $TMP
NTttcp (Windows only)
The program can be installed by running this installer: NTttcp.msi
Note that we are not the authors of the above installer. Please use your anti-virus software to scan the file before using it.
After completing the installation, go to the installation directory, and make two copies of `ntttcp.exe`:
- `ntttcpr.exe` --- use for receiving traffic
- `ntttcps.exe` --- use for sending traffic
For usage guidelines, please refer to the guide in the installation directory.
Diagnostic tools
There are many diagnostic tools one can use:
- Performance tab in VM's Task Manager;
- Performance tab for the VM in XenCenter;
- Performance tab for the VM's host in XenCenter;
- `top` (with z and 1 pressed) in VM's host's `dom0`; and,
- `xentop` in VM's host's `dom0`.
It is sometimes also worth observing `/proc/interrupts` in `dom0`, as well as `/proc/irq/<irqno>/smp_affinity`.
Recommended configurations
When reading this section, please see the Tweaks below it for reference.
CPU bottleneck
All network throughput tests were, in the end, bottlenecked by VCPU capacity. This means that machines with better physical CPUs are expected to achieve higher network throughputs for both `dom0` and VM tests.
Number of VM pairs and threads
If one is interested in achieving a high aggregate network throughput of VMs on a host, it is crucial to consider both the number of VM pairs and the number of network transmitting/receiving threads in each VM. Ideal values for these numbers vary from OS to OS due to different networking stack implementations, so some experimentation is recommended --- finding a good balance can have a drastic effect on network performance (mainly due to better VCPU utilisation). Our research shows that 8 pairs with 2 `iperf` threads per pair works well for Debian-based Linux, while 4 pairs with 8 `iperf` threads per pair works well for Windows 7.
Allocation of NICs over `netback` threads
All results above assume equal distribution of used NICs over available `netback` threads, which may not always be possible --- see a KB article for more information. For VM network throughput, it is important to get as close as possible to equal distribution in order to make efficient use of the available VCPUs.
Using irqbalance
The `irqbalance` daemon is enabled by default. It has been observed that this daemon can improve VM network performance by about 16% --- note that this is much less than the potential gain of the getting the other points described in this section right. The reason why `irqbalance` can help is that it distributes the processing of `dom0`-level interrupts across all available `dom0` VCPUs, not just the first one.
Optimising Windows VMs (and other HVM guests)
It appears that Xen currently feeds all interrupts for a guest to the guest's first VCPU, i.e. `VCPU0`. Initial observations show that more CPU cycles are spent processing the interrupt requests than actually processing the received data (assuming there is no disk I/O, which is slow). This means that, on a Windows VM with 2 VCPUs, all processing of the received data should be done on the second VCPU, i.e. `VCPU1`: Task Manager > Processes > Select Process > Set CPU affinity > 1 --- in this case, `VCPU0` will be fully used, whereas `VCPU1` will probably have some spare cycles. While this is acceptable, it is more efficient to use 2 guests (1 VCPU each), which makes full use of both VCPUs. Therefore, to avoid this bottleneck altogether, one should probably use "`<number of host CPUs> - 4`" VMs, each with 1 VCPU, and combine their capabilities with a NetScaler Appliance.
Offloading some network processing to NICs
Network offloading is not officially supported, since there are known issues with some drivers. That said, if your NIC supports offloading, try to use it, especially Generic Receive Offload (GRO). However, please verify carefully that it works for your NIC+driver before using it in a production environment.
If performing mainly `dom0`-to-`dom0` network traffic, turning on GRO setting for the NICs involved can be highly beneficial when combined with the `irqbalance` daemon (see above). This configuration can easily be combined with Open vSwitch (the default option), since the performance is either equal or faster than with a Linux Bridge. Turning on the Large Receive Offload (LRO) setting tends to, in general, decrease `dom0` network throughput.
Our initial test results indicate that turning on either of the two offload settings (GRO or LRO) in dom0 can give mixed results based on the context. Feel free to experiment and let us know your findings.
Jumbo frames
Note that jumbo frames for the connection from A to B only work when every part of the connection supports (and has enabled) MTU 9000. See the Tweaks section below for information on how to enable this in some contexts.
We have observed network performance gains for VM-to-VM traffic (where VMs are on different hosts). Where the VMs were Linux PV guests, we were able to enable GRO offloading in hosts' dom0, which provided a further speedup.
Open vSwitch
In the various tests that we performed, we observed no statistically significant difference in network performance for dom0-to-dom0 traffic. We observed from 3% (Linux PV guests, no `irqbalance`) to about %10 (Windows HVM guests, with `irqbalance`) worse performance for VM-to-VM traffic.
TCP settings
Our experiments show that tweaking TCP settings inside the `VM`(s) can lead to substantial network performance improvements. The main reason for this is that most systems are still by default configured to work well on 100Mb/s or 1Gb/s, not 10Gb/s, NICs. The Tweaks section below contains a section about the recommended TCP settings for a VM.
Using SR-IOV
SR-IOV is currently a double-edged sword. This section explains what SR-IOV is, what are its down sides, and what its benefits.
Single Root I/O Virtualisation (SR-IOV) is a PCI device virtualisation technology that allows a single PCI device to appear as multiple PCI devices on the physical PCI bus. The actual physical device is known as a Physical Function (PF) while the others are known as Virtual Functions (VF). The purpose of this is for the hypervisor to directly assign one or more of these VFs to a Virtual Machine (VM) using SR-IOV technology: the guest can then use the VF as any other directly assigned PCI device. Assigning one or more VFs to a VM allows the VM to directly exploit the hardware. When configured, each VM behaves as though it is using the NIC directly, reducing processing overhead and improving performance.
SR-IOV can be used only with architectures that support IOMMU and NICs that support SR-IOV; there could be further compatibility constraints by the architecture or the NIC. Please contact support or ask on forums about recommended/officially supported configurations.
If your VM has an SR-IOV VF, functions that require VM mobility, for example, Live Migration, Workload Balancing, Rolling Pool Upgrade, High Availability and Disaster Recovery, are not possible. This is because the VM is directly tied to the physical SR-IOV enabled NIC VF. In addition, VM network traffic sent via an SR-IOV VF bypasses the vSwitch, so it is not possible to create ACLs or view QoS.
Our experiments show that a single-VCPU VM using SR-IOV on a modern system can (together with the usual NIC offloading features enabled) saturate (or nearly saturate) a 10Gbps connection when receiving traffic. Furthermore, the impact on `dom0` is negligible.
The Tweaks section below contains a section about how to enable SR-IOV.
Tweaks
Automatic IRQ Balancing in Dom0
`irqbalance` is enabled by default.
If IRQ balancing service is already installed, you can enable it by running:
service irqbalance start
Otherwise, you need to install it first with:
yum --disablerepo=citrix --enablerepo=base,updates install -y irqbalance
Manual IRQ Balancing in Dom0
While `irqbalance` does the job in most situations, manual IRQ balancing can prove better in some situations. If we have a `dom0` with 4 VCPUs, the following script disables `irqbalance`, and evenly distributes specific interrupt queues (1272--1279) among the available VCPUs:
service irqbalance stop for i in `seq 0 7`; do queue=$((1272 + i)); aff=$((1 << i % 4)); printf "%x" $aff > /proc/irq/$queue/smp_affinity; done
To find out how many `dom0` VCPUs a host has, use `cat /proc/cpuinfo`. To find
out what interrupt queues correspond to which interface, use `cat
/proc/interrupts`.
Changing the Number of Dom0 VCPUs
To check the current number of `dom0` VCPUs, run `cat /proc/cpuinfo`.
The desired number of `dom0` VCPUs can be set in `/etc/sysconfig/unplug-vcpus`.
For this to take effect, you can either restart the host, or (only in the case where the number of VCPUs in `dom0` is decreasing) run:
/etc/init.d/unplug-vcpus start
Changing the Number of Netback Threads in Dom0
By default, the number of netback threads in `dom0` equals `min(4,<number_of_vcpus_in_dom0>)`. Therefore, increasing the number of `dom0` VCPUs above 4, will by default not increase the number of netback threads.
To increase the threshold number of netback threads to 12, write `xen-netback.netback_max_groups=12` into `/boot/extlinux.conf` under section labelled `xe-serial` just after the assignment `console=hvc0`.
Enabling NIC Offloading
Please see the "Offloading some network processing to NICs" section above.
You can use `ethtool` to enable/disable NIC offloading.
ETH=eth6 # the conn. for which you want to enable offloading ethtool -k $ETH # check what is currently enabled/disabled ethtool -K $ETH gro on # enable GRO
Note that changing offload settings directly via `ethool` will not persist the
configuration through host reboots; to do that, use `other-config` of the `xe`
command.
xe pif-param-set uuid=<pif_uuid> other-config:ethtool-gro=on
Enabling Jumbo Frames
Suppose `eth6` and `xenbr6` are the device and the bridge corresponding to the 10 GiB/sec connection used.
Shut down user domains:
VMs=$(xe vm-list is-control-domain=false params=uuid --minimal | sed 's/,/ /g') for uuid in $VMs; do xe vm-shutdown uuid=$uuid; done
Set network MTU to 9000, and re-plug relevant PIFs:
net_uuid=`xe network-list bridge=xenbr6 params=uuid --minimal` xe network-param-set uuid=$net_uuid MTU=9000 PIFs=$(xe pif-list network-uuid=$net_uuid --minimal | sed 's/,/ /g') for uuid in $PIFs; do xe pif-unplug uuid=$uuid; xe pif-plug uuid=$uuid; done
Start user domains (you might want to make sure that VMs are started one after
another to avoid potential VIF static allocation problems):
VMs=$(xe vm-list is-control-domain=false params=uuid --minimal | sed 's/,/ /g') for uuid in $VMs; do xe vm-start uuid=$uuid; done
Set up the connections you will use inside the user domains to use MTU 9000. For
Linux VMs, this is done with:
ETH=eth1 # the user domain connection you are concerned with ifconfig $ETH mtu 9000 up
Verifying:
xe vif-list network-uuid=$net_uuid params=MTU --minimal
Linux TCP parameter settings
Default in Dom0
ETH=eth6 # the connection you are concerned with sysctl -w net.core.rmem_max=131071 sysctl -w net.core.wmem_max=131071 sysctl -w net.ipv4.tcp_rmem="4096 87380 3080192" sysctl -w net.ipv4.tcp_wmem="4096 16384 3080192" sysctl -w net.core.netdev_max_backlog=1000 sysctl -w net.ipv4.tcp_congestion_control=reno ifconfig $ETH txqueuelen 1000 ethtool -K $ETH gro off sysctl -w net.ipv4.tcp_timestamps=1 sysctl -w net.ipv4.tcp_sack=1 sysctl -w net.ipv4.tcp_fin_timeout=60
Default for a Demo Etch Linux VM
ETH=eth1 # the connection you are concerned with sysctl -w net.core.rmem_max=109568 sysctl -w net.core.wmem_max=109568 sysctl -w net.ipv4.tcp_rmem="4096 87380 262144" sysctl -w net.ipv4.tcp_wmem="4096 16384 262144" sysctl -w net.core.netdev_max_backlog=1000 sysctl -w net.ipv4.tcp_congestion_control=bic ifconfig $ETH txqueuelen 1000 ethtool -K $ETH gso off sysctl -w net.ipv4.tcp_timestamps=1 sysctl -w net.ipv4.tcp_sack=1 sysctl -w net.ipv4.tcp_fin_timeout=60
Recommended TCP settings for Dom0
Changing these settings in only relevant if you want to optimise network connections for which one of the end-points is `dom0` (not a user domain). Using settings recommended for a user domain (VM) will work well for `dom0` as well.
Recommended TCP settings for a VM
Bandwidth Delay Product (BDP) = Route Trip Time (RTT) * Theoretical Bandwidth Limit
For example, if RTT = 100ms = .1s, and theoretical bandwidth is 10Gbit/s, then:
BDP = (.1s) * (10 * 10^9 bit/s) = 10^9 bit = 1 Gbit ~= 2^30 bit = 134217728 B
ETH=eth6 # ESSENTIAL (large benefit) sysctl -w net.core.rmem_max=134217728 # BDP sysctl -w net.core.wmem_max=134217728 # BDP sysctl -w net.ipv4.tcp_rmem="4096 87380 134217728" # _ _ BDP sysctl -w net.ipv4.tcp_wmem="4096 65536 134217728" # _ _ BDP sysctl -w net.core.netdev_max_backlog=300000 modprobe tcp_cubic sysctl -w net.ipv4.tcp_congestion_control=cubic ifconfig $ETH txqueuelen 300000 # OPTIONAL (small benefit) ethtool -K $ETH gso on sysctl -w net.ipv4.tcp_sack=0 # for reliable networks only sysctl -w net.ipv4.tcp_fin_timeout=15 # claim resources sooner sysctl -w net.ipv4.tcp_timestamps=0 # does not work with GRO on in dom0
Checking existing settings:
ETH=eth6 sysctl net.core.rmem_max sysctl net.core.wmem_max sysctl net.ipv4.tcp_rmem sysctl net.ipv4.tcp_wmem sysctl net.core.netdev_max_backlog sysctl net.ipv4.tcp_congestion_control ifconfig $ETH | grep -o "txqueuelen:[0-9]\+" ethtool -k $ETH 2> /dev/null | grep "generic.segmentation.offload" sysctl net.ipv4.tcp_timestamps sysctl net.ipv4.tcp_sack sysctl net.ipv4.tcp_fin_timeout
Pinning a VM to specific CPUs
While this does not necessarily improve performance (it can easily make performance worse, in fact), it is useful when debugging CPU usage of a VM. To assign a VM to CPUs 3 and 4, run the following in `dom0`:
xe vm-param-set uuid=<vm-uuid> VCPUs-params:mask=3,4
Switching between Linux Bridge and Open VSwitch
To see what network backend you are currently using, run in `dom0`:
cat /etc/xensource/network.conf
To switch to using the Linux Bridge network backend, run in `dom0`:
xe-switch-network-backend bridge
To switch to using Open VSwtich network backend, run in `dom0`:
xe-switch-network-backend openvswitch
Enabling/disabling IOMMU
This is, in fact, not a tweak, but a requirement when using SR-IOV (see below).
Some versions of Xen have IOMMU enabled by default. If disabled, you can enable it by editing `/boot/extlinux.conf`, and adding `iommu=1` to Xen parameters (i.e. just before the first `---` of your active configuration). If enabled by default, you can disable it by using `iommu=0`, instead.
Enabling SR-IOV
Make sure that IOMMU is enabled in the version of Xen that you are running --- see section above.
In `dom0`, use `lspci` to display a list of Virtual Functions (VFs). For example,
07:10.0 Ethernet controller: Intel Corporation 82559 Ethernet Controller Virtual Function (rev 01)
In the example above, `07:10.0` is the `bus:device.function` address of the VF.
Assign a free (non-assigned) VF to the target VM by running:
xe vm-param-set other-config:pci=0/0000:<bus:device.function> uuid=<vm-uuid>
(Re-)Start the VM, and install the appropriate VF driver (inside your VM) for
your specific NIC.
You can assign multiple VFs to a single VM; however, the same VF cannot be shared across multiple VMs.
Acknowledgements
While this guide was mostly written by Rok Strniša, it could not have been nearly as good without the help and advice from many of his colleagues, including (in alphabetic order) Alex Zeffertt, Dave Scott, George Dunlap, Ian Campbell, James Bulpin, Jonathan Davies, Lawrence Simpson, Marcus Granado, Mike Bursell, Paul Durrant, Rob Hoes, Sally Neale, and Simon Rowe.